Phone and Instrument cable for TMC vessels identified according to JIS standards include the following types of codes / signs:
150/250V TTY, FA-TTY & 150/250V TTYC, FA-TTYC & 150/250V TTYCY, FA-TTYCY # 150/250V TTYSLA, FA- TTYSLA & 150/250V TTYCSLA, FA- TTYCSLA & 150/250V TTYCYSLA, FA- TTYCYSLA #150/250V TTY-SLA, FA- TTY-SLA & 150/250V TTYC-SLA, FA- TTYC-SLA & 150/250V TTYCY-SLA, FA- TTYCY-SLA #250V RCOP(OS) #250V RCOP(IS) #250V FR-RCOP(OS) #250V FR-RCOP(IS)
1 – Phone and Instrument cable for ships, common type
Cable identity:
– 150/250V TTY, FA-TTY,
– 150/250V TTYC, FA-TTYC,
– 150/250V TTYCY, FA-TTYCY
Applicable standards:
– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FA-Cables Only)
– Mechanical impact: CSA 22.2 No. 0.3 (-40°C/-35oC) (Cold Type Only)
– Maximum conduction temperature: 70°C
![]() |
Phone and Instrument cable for ships, common types, TMC Korea |
Structure:
Group | Code | Details |
Conducting cores | Tt | Plain copper wire is ram (annealed) according to JIS C 3410(2010) |
Electric | PVC according to JIS C 3410(2010) – 2 electric cores are twisted with fast in pairs – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice | |
Cable case | Y | PVC according to JIS C 3410(2010) |
Wrapped mesh layer | C | Zinc Dip Steel Braided Mesh Coverage Density: Smallest 90% – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint |
Outer sheath | Y | PVC according to JIS C 3410(2010) Shell Color: Black Separate color options according to customer requirements |
Identity color | – Print the number of each pair above alphabetically on the white cable, wallet e.g. (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B) – 1T, 1Q cable is determined by the black number on the white cable |
2 – Phone and Instrument cable for ships, general anti-interference type
Cable identity:
– 150/250V TTYSLA, FA-TTYSLA,
– 150/250V TTYCSLA, FA-TTYCSLA,
– 150/250V TTYCYSLA, FA-TTYCYSLA
Applicable standards:
– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FA-Cables Only)
– Mechanical impact: CSA 22.2 No. 0.3 (-40°C/-35oC) (Cold Type Only)
– Maximum conduction temperature: 70°C
![]() |
TMC Korea telephone cables and equipment for #Dùng for #Loại anti-interference vessels |
Structure:
Group | Code | Details |
Conducting cores | Tt | Plain copper wire is ram (annealed) according to JIS C 3410(2010) |
Electric | PVC according to JIS C 3410(2010) – 2 electric cores are twisted with fast in pairs – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice | |
Anti-interference | Sla | Anti-interference with tin-plated copper wire Ice layer options suitable for general anti-interference layer |
Cable case | Y | PVC according to JIS C 3410(2010) |
Wrapped mesh layer | C | Zinc Dip Steel Braided Mesh Coverage Density: Smallest 90% – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint |
Outer sheath | Y | PVC according to JIS C 3410(2010) Shell Color: Black Separate color options according to customer requirements |
Identity color | – Print the number of each pair above alphabetically on the white cable, wallet e.g. (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B) – 1T, 1Q cable is determined by the black number on the white cable |
3 – Phone and Instrument cable for ships, individual anti-interference type each strand
Cable identity:
– 150/250V TTY-SLA, FA-TTY-SLA,
– 150/250V TTYC-SLA, FA-TTYC-SLA,
– 150/250V TTYCY-SLA, FA-TTYCY-SLA
Applicable standards:
– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FA-Cables Only)
– Mechanical impact: CSA 22.2 No. 0.3 (-40°C/-35oC) (Cold Type Only)
– Maximum conduction temperature: 70°C
![]() |
Separate anti-interference telephone cable for each pair, for ships, TMC |
Structure:
Group | Code | Details |
Conducting cores | Tt | Plain copper wire is ram (annealed) according to JIS C 3410(2010) |
Electric | PVC according to JIS C 3410(2010) – 2 electric cores are twisted with fast in pairs – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice | |
Anti-interference | -SLA | Anti-interference with tin-plated copper wire Ice layer options are suitable for individual anti-interference layers for each strand |
Cable case | Y | PVC according to JIS C 3410(2010) |
Wrapped mesh layer | C | Zinc Dip Steel Braided Mesh Coverage Density: Smallest 90% – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint |
Outer sheath | Y | PVC according to JIS C 3410(2010) Shell Color: Black Separate color options according to customer requirements |
Identity color | – Print the number of each pair above alphabetically on the white cable, wallet e.g. (1A, 1B), (2A, 2B), (3A, 3B), (4A, 4B) |
For more information, please visit the product page:
by TESIN VIETNAM