TMC’s watercraft and lighting cables are identified according to JIS standards including the following types of codes / signs:
0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY & 0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY
0.6/1kV D(T,F,5,6,10)PY, FA-D(T,F,5,6,10)PY & 0.6/1kV D(T,F,5,6,10)PYC, FA-D(T,F,5,6,10)PYC & 0.6/1kV D(T,F,5,6,10)PYCY, FA-D(T,F,5,6,10)PYCY / 0.6/1kV D(T)PYE, D(T)PYCE, D(T)PYCYE
0.6/1kV DPYSLA, TPYSLA, FA-DPYSLA, FA-TPYSLA & 0.6/1kV DPYCSLA, TPYCSLA, FA-DPYCSLA, FA-TPYCSLA & 0.6/1kV DPYCYSLA, TPYCYSLA, FA-DPYCYSLA, FA-TPYCYSLA
0.6/1kV FR-DPY, FR-TPY, FR-FA-DPY, FR-FA-TPY & 0.6/1kV FR-DPYC, FR-TPYC, FR-FA-DPYC, FR-FA-TPYC & 0.6/1kV FR-DPYCY, FR-TPYCY, FR-FA-DPYCY, FR-FA-TPYCY
1 – Single type lighting cable and power cable for seagoing vessels
Cable identity:
– 0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY
– 0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY
Applicable standards:
– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FA-Cables Only)
– Mechanical impact: CSA 22.2 No. 0.3 (-40oC/-35oC) (Cold Type Only)
– Maximum conduction temperature: 90°C
![]() |
1 core marine electric cable structure |
Structure:
Group | Code | Details |
Conducting cores | S | Tin coated copper wire according to JIS C 3410(2010) |
Electric | P | EPR rubber according to JIS C 3410(2010) – Electrolysed cable core – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice |
Cable case | Y | PVC according to JIS C 3410(2010) |
Wrapped mesh layer |
C (CB) | Zinc dip steel braided mesh or copper mesh Coverage Density: Smallest 90% Layer-by-layer tape options – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint |
Outer sheath | Y | PVC according to JIS C 3410(2010) Shell Color: Black Separate color options according to customer requirements |
2 – Power cable and multi-core lighting cable for ships
Cable identity:
– 0.6/1kV D(T,F,5,6,10)PY, FA-D(T,F,5,6,10)PY
– 0.6/1kV D(T,F,5,6,10)PYC, FA-D(T,F,5,6,10)PYC
– 0.6/1kV D(T,F,5,6,10)PYCY, FA-D(T,F,5,6,10)PYCY
– 0.6/1kV D(T)PYE, D(T)PYCE, D(T)PYCYE
Applicable standards:
– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FA-Cables Only)
– Mechanical impact: CSA 22.2 No. 0.3 (-40oC/-35oC) (Cold Type Only)
– Maximum conduction temperature: 90°C
![]() |
TMC Marine Electric Cable Structure – Multi-Core Type |
Structure:
Group | Code | Details |
Conducting cores | D, T, F 5, 6, 10 | Tin coated copper wire according to JIS C 3410(2010) Optionally each appropriate dressing layer |
Electric | P | EPR rubber according to JIS C 3410(2010) – Electrolysed cable core – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice |
Cable case | Y | PVC according to JIS C 3410(2010) |
Wrapped mesh layer | C | Zinc Dip Steel Braided Mesh Coverage Density: Smallest 90% – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint |
Outer sheath | Y | PVC according to JIS C 3410(2010) Shell Color: Black Separate color options according to customer requirements |
Identity color | Number of cores | Inland | No contact |
2C | Black, White | – | |
3C / 2C+E | Black, White, Red | Black, White, Yellow-Blue | |
4C / 3C+E | Black, white, red, blue | Black, White, Red, Yellow-Blue | |
5C and more | Black, white numbering | Black, white, yellow-blue numbering |
3 – Power cable and double lighting cable and 3 with anti-interference for marine field
Cable identity:
– 0.6/1kV DPYSLA, TPYSLA, FA-DPYSLA, FA-TPYSLA
– 0.6/1kV DPYCSLA, TPYCSLA, FA-DPYCSLA, FA-TPYCSLA
– 0.6/1kV DPYCYSLA, TPYCYSLA, FA-DPYCYSLA, FA-TPYCYSLA
Applicable standards:
– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FA-Cables Only)
– Mechanical impact: CSA 22.2 No. 0.3 (-40oC/-35oC) (Cold Type Only)
– Maximum conduction temperature: 90°C
![]() |
TMC electric cable structure – Multi-core type and anti-interference |
Structure:
Group | Code | Details |
Conducting cores | D, T | Tin coated copper wire according to JIS C 3410(2010) Optionally each appropriate dressing layer |
Electric | P | EPR rubber according to JIS C 3410(2010) – Electrolysed cable core – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice |
Anti-interference | Sla | Anti-interference with tin-plated copper wire Ice layer options suitable for general anti-interference layer |
Cable case | Y | PVC according to JIS C 3410(2010) |
Wrapped mesh layer | C | Zinc Dip Steel Braided Mesh Coverage Density: Smallest 90% – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint |
Outer sheath | Y | PVC according to JIS C 3410(2010) Shell Color: Black Separate color options according to customer requirements |
Identity color | Number of cores | Color of the electrical layer |
2C | Black, White | |
3C | Black, White, Red |
4 – Power cable and double lighting cable and 3 with fire retardant for ship
Cable identity:
– 0.6/1kV FR-D(T)PY, FR-FA-D(T)PY
– 0.6/1kV FR-D(T)PYC, FR-FA-D(T)PYC
– 0.6/1kV FR-D(T)PYCY, FR-FA-D(T)PYCY
Applicable standards:
– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FR-FA-Cables Only)
– Fire retardant: IEC 60331-21 / IEC 60331-1, -2 (120minute)
– Mechanical impact: CSA 22.2 No. 0.3 (-40oC/-35oC) (Cold Type Only)
– Maximum conduction temperature: 90°C

TMC fire retardant cable structure – For ships and ships
Structure:
Group | Code | Details |
Conducting cores | D, T | Tin coated copper wire according to JIS C 3410(2010) Optionally each appropriate dressing layer |
Fire retardant | FR-(FA-) | Mica tape/glass tape |
Electric | P | EPR rubber according to JIS C 3410(2010) – Electrolysed cable core – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice |
Cable case | Y | PVC according to JIS C 3410(2010) |
Wrapped mesh layer | C | Zinc Dip Steel Braided Mesh Coverage Density: Smallest 90% – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint |
Outer sheath | Y | PVC according to JIS C 3410(2010) Shell Color: Black Separate color options according to customer requirements |
Identity color | Number of cores | Color of the electrical layer |
2C | Black, White | |
3C | Black, White, Red |
For more information, please visit the product page:
by TESIN VIETNAM