TMC electric cable code/sign meaning #2: Power cable

TMC’s watercraft and lighting cables are identified according to JIS standards including the following types of codes / signs:

0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY & 0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY

0.6/1kV D(T,F,5,6,10)PY, FA-D(T,F,5,6,10)PY & 0.6/1kV D(T,F,5,6,10)PYC, FA-D(T,F,5,6,10)PYC & 0.6/1kV D(T,F,5,6,10)PYCY, FA-D(T,F,5,6,10)PYCY / 0.6/1kV D(T)PYE, D(T)PYCE, D(T)PYCYE

0.6/1kV DPYSLA, TPYSLA, FA-DPYSLA, FA-TPYSLA & 0.6/1kV DPYCSLA, TPYCSLA, FA-DPYCSLA, FA-TPYCSLA & 0.6/1kV DPYCYSLA, TPYCYSLA, FA-DPYCYSLA, FA-TPYCYSLA

0.6/1kV FR-DPY, FR-TPY, FR-FA-DPY, FR-FA-TPY & 0.6/1kV FR-DPYC, FR-TPYC, FR-FA-DPYC, FR-FA-TPYC & 0.6/1kV FR-DPYCY, FR-TPYCY, FR-FA-DPYCY, FR-FA-TPYCY

1 – Single type lighting cable and power cable for seagoing vessels

Cable identity:

– 0.6/1kV SPYC, SPYCY, FA-SPYC, FA-SPYCY
– 0.6/1kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY

Applicable standards:

– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FA-Cables Only)
– Mechanical impact: CSA 22.2 No. 0.3 (-40oC/-35oC) (Cold Type Only)
– Maximum conduction temperature: 90°C

1 core marine electric cable structure
1 core marine electric cable structure

Structure:

Group Code Details
Conducting cores S Tin coated copper wire according to JIS C 3410(2010)
Electric P EPR rubber according to JIS C 3410(2010)   – Electrolysed cable core – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice
Cable case Y PVC according to JIS C 3410(2010)
Wrapped mesh layer C
(CB)
Zinc dip steel braided mesh or copper mesh   Coverage Density: Smallest 90% Layer-by-layer tape options – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint
Outer sheath Y PVC according to JIS C 3410(2010)   Shell Color: Black Separate color options according to customer requirements

2 – Power cable and multi-core lighting cable for ships

Cable identity:

– 0.6/1kV D(T,F,5,6,10)PY, FA-D(T,F,5,6,10)PY
– 0.6/1kV D(T,F,5,6,10)PYC, FA-D(T,F,5,6,10)PYC
– 0.6/1kV D(T,F,5,6,10)PYCY, FA-D(T,F,5,6,10)PYCY
– 0.6/1kV D(T)PYE, D(T)PYCE, D(T)PYCYE

Applicable standards:

– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FA-Cables Only)
– Mechanical impact: CSA 22.2 No. 0.3 (-40oC/-35oC) (Cold Type Only)
– Maximum conduction temperature: 90°C

TMC Marine Electric Cable Structure - Multi-Core Type
TMC Marine Electric Cable Structure – Multi-Core Type

Structure:

Group Code Details
Conducting cores D, T, F   5, 6, 10 Tin coated copper wire according to JIS C 3410(2010)   Optionally each appropriate dressing layer
Electric P EPR rubber according to JIS C 3410(2010)   – Electrolysed cable core – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice
Cable case Y PVC according to JIS C 3410(2010)
Wrapped mesh layer C Zinc Dip Steel Braided Mesh   Coverage Density: Smallest 90% – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint
Outer sheath Y PVC according to JIS C 3410(2010)   Shell Color: Black Separate color options according to customer requirements
Identity color Number of cores Inland No contact
  2C Black, White
  3C / 2C+E Black, White, Red Black, White, Yellow-Blue
  4C / 3C+E Black, white, red, blue Black, White, Red, Yellow-Blue
  5C and more Black, white numbering Black, white, yellow-blue numbering

3 – Power cable and double lighting cable and 3 with anti-interference for marine field

Cable identity:

– 0.6/1kV DPYSLA, TPYSLA, FA-DPYSLA, FA-TPYSLA
– 0.6/1kV DPYCSLA, TPYCSLA, FA-DPYCSLA, FA-TPYCSLA
– 0.6/1kV DPYCYSLA, TPYCYSLA, FA-DPYCYSLA, FA-TPYCYSLA

Applicable standards:

– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FA-Cables Only)
– Mechanical impact: CSA 22.2 No. 0.3 (-40oC/-35oC) (Cold Type Only)
– Maximum conduction temperature: 90°C

TMC electric cable structure - Multi-core type and anti-interference
TMC electric cable structure – Multi-core type and anti-interference

Structure:

Group Code Details
Conducting cores D, T Tin coated copper wire according to JIS C 3410(2010)   Optionally each appropriate dressing layer
Electric P EPR rubber according to JIS C 3410(2010)   – Electrolysed cable core – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice
Anti-interference Sla Anti-interference with tin-plated copper wire   Ice layer options suitable for general anti-interference layer
Cable case Y PVC according to JIS C 3410(2010)
Wrapped mesh layer C Zinc Dip Steel Braided Mesh   Coverage Density: Smallest 90% – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint
Outer sheath Y PVC according to JIS C 3410(2010)   Shell Color: Black Separate color options according to customer requirements
Identity color Number of cores Color of the electrical layer
  2C Black, White
  3C Black, White, Red

4 – Power cable and double lighting cable and 3 with fire retardant for ship

Cable identity:

– 0.6/1kV FR-D(T)PY, FR-FA-D(T)PY
– 0.6/1kV FR-D(T)PYC, FR-FA-D(T)PYC
– 0.6/1kV FR-D(T)PYCY, FR-FA-D(T)PYCY

Applicable standards:

– Design: JIS C 3410(2010)
– Slow fire: IEC 60332-1, IEC 60332-3 Category A (FR-FA-Cables Only)

– Fire retardant: IEC 60331-21 / IEC 60331-1, -2 (120minute)
– Mechanical impact: CSA 22.2 No. 0.3 (-40oC/-35oC) (Cold Type Only)
– Maximum conduction temperature: 90°C

TMC fire retardant cable structure - For ships and ships

TMC fire retardant cable structure – For ships and ships

Structure:

Group Code Details
Conducting cores D, T Tin coated copper wire according to JIS C 3410(2010)   Optionally each appropriate dressing layer
Fire retardant FR-(FA-) Mica tape/glass tape
Electric P EPR rubber according to JIS C 3410(2010)   – Electrolysed cable core – Moisture filtration and slow burning options – Optionally 1 or more appropriate layers of ice
Cable case Y PVC according to JIS C 3410(2010)
Wrapped mesh layer C Zinc Dip Steel Braided Mesh   Coverage Density: Smallest 90% – White paint for zinc-embedded steel mesh – If there is an external PVC case, there is no need to paint
Outer sheath Y PVC according to JIS C 3410(2010)   Shell Color: Black Separate color options according to customer requirements
Identity color Number of cores Color of the electrical layer
  2C Black, White