Hệ thống LMS hiển thị thời gian thực

Introduction of Finetek LMS-300 fuel depot management system

LMS-300 # Fuel Management System

ATG System – The automatic tank level measurement system works thanks to the high-precision EG series continuous level measurement sensor, which is capable of continuously monitoring the level of fluid in the tank, displaying the level of the screen remotely and being able to raise the alarm at the pre-set thresholds.

EG series type alarm sensor

LMS-300 System Home Screen

EG series type alarm sensorLMS-300 System Home Screen

Why ATG?

Diagram of installation of buoys for petroleum tank depots
  • Continuous inventory tracking
  • Plan delivery and order shelves
  • Environmental protection, leak detection
  • Operational safety
  • Avoid losses
  • Conformity with regulations

ATG System Diagram

ATG System Diagram

ATG System Diagram

EG37 explosion level alarm sensor specifications

Buoy-type continuous level sensor - fake word

Integrated 2 floats – 1 float for water, 1 float for liquid (gasoline, oil)

Accuracy: +/- 1.0 mm, Resolution:+/- 0.004% F.S.
Leak detection: 0.76 Litre/Hour
Five Thermistors – Temp. Accuracy +/- 0.5 °C; Resolution+/- 0.1 °C
Working temperature: -40°C to 200°C Certified
by ATEX for use in Class A/Class B products
Protection level: IP 67 (Housing) IP69K (Probe) certified Easy installation

Durable, strong, high reliability, less maintenance required

EG36 explosion-level continuous level sensor #Có on-site display

EG36 Level Alarm Sensor With On-Premises Display

Integrated 2 floats – 1 float for water, 1 float for liquid (gasoline, oil)

Accuracy: +/- 1.0 mm, Resolution:+/- 0.004% F.S.
Leak detection: 0.76 Litre/Hour
Five Thermistors – Temp. Accuracy +/- 0.5 °C; Resolution+/- 0.1 °C
Working temperature: -40°C to 125°C Standard
Conformity Certification: Certified by ATEX for use in Class A/Class B products
Protection level: IP 67 (Housing) IP69K (Probe) certified Easy installation

Durable, strong, high reliability, less maintenance required

Principle 2 floats, 1 for rows, 1 for water

Finetek LMS-300 Tank Warehouse Management System

Buoys for goods (gasoline, oil):

  • This float only floats on the surface of the goods, in which the height of the goods is in the tank.

Water float:

  • This buoy only floats on the surface of the water and is submerged in gasoline because of its large proportion
  • than gasoline but lighter than water. This buoy will tell the height of the water part in the tank.
  • This is an additional option if desired

Alarm points of the system:

Including: High water level newspaper, too high water level newspaper, too low oil level newspaper, low oil level newspaper, high oil level alarm and too high alarm

Alarm milestones of petroleum storage level monitoring system
Alarm milestones of petroleum storage level monitoring system

The main features of the LMS-300 ATG Console

LMS System Control Cabinet
  • 7-inch color display
  • Can connect at 6 tanks
  • User-friendly interface, easy to use and access data
  • Show fuel level and volume
  • Fuel temperature display
  • Display water level and volume
  • Automatically receive data
  • Proportional options
  • TC Volume @ 15 degrees
  • 0.76 Litre/Hour Leak Detection
  • Schedule reports by day/week/month
  • Check the ashes in 1 minute
  • Report by Email/SMS/Fax
  • Integrated output relays for inter-dynamic applications
  • Can connect additional relay modules
  • Other connection outputs RS232/USB, RJ-45

LMS-300 ATG Console – Inventory

LMS-300 ATG Console – Inventory

LMS-300 ATG Console – Tank Settings

LMS-300 ATG Console – Tank Settings
 

LMS-300 ATG Console – Data Recording

LMS-300 ATG Console – Data Recording

LMS-300 ATG Console – Configuration settings

 LMS-300 ATG Console – Configuration settings

LMS-300 ATG Console – Access alarm schedule

LMS-300 ATG Console - Access alarm schedule

LMS-300 ATG Console – Printer

LMS-300 ATG Console – Access LMS-300 ATG Console – Printer

LMS-300 ATG Console – Experience

  • Mining industry has a huge inventories of fuel for remote mining works
  • Application: Diesel Tanks, Storage Lubricating Tanks, AdBlue etc.
  • Sensor Used: EG37
Installation of the system
  • Controlling diesel theft for Telecom stations.
  • Dual floats for diesel and water.
  • Theft alerts
Typical works have installed fuel storage monitoring system

Refer to the specifications of the EG sensor used in the system