Description
Honeywell BW Max XT II (GasAlertMax XT II) Confined space Multigas detector for detect LEL O2 CO H2S, Go the distance, and save.
The most popular order number: XT-XWHM-Y-OE, XT = Max XT II; XWHM = LEL O2 CO H2S; Y = Yellow; OE = 220V 2pin plug.
GasAlertMax XT II is the smart, simple, economical way to compliance. Workers feel safe and incidents are minimized so everyone will be able to do more. That means savings realized from business continuity and productivity
Simple operation, with SmartSample pump
GasAlertMax XT II reliably monitors up to four hazards and combines straightforward one-button operation, a robust, motorized pump for remote sampling, and now features IntelliFlash™, the flashing LED compliance indicator that tells you at-a-glance your gas detector is functioning correctly. The GasAlertMax XT II is fully compatible with MicroDock II automated test and calibration system.
Standard Package Contents
- Detector complete with specified sensor(s), stainless steel alligator clip and concussion-proof housing
- Rechargeable battery
- Wall outlet charging adaptor
- 3 ft. / 1 m calibration hose with quick connect
- 10 ft. / 3 m sampling hose with particulate filter and quick connect
- Reversible screwdriver
- Kit of spare pump filters (5 particulate and 5 hydrophobic)
- Manual

Filtered combustible (%LEL) sensor configurations for Honeywell BW Max XT II gas detector
GasAlertMax XT II 4-Gas Detector | Yellow | Black |
GasAlert Max XT II %LEL(F) O2 H2S CO | XT-XWHM-Y-NA | XT-XWHM-B-NA |
GasAlertMax XT II 3-Gas Detector | Yellow | Black |
GasAlert Max XT II %LEL(F) O2 H2S | XT-XWH0-Y-NA | XT-XWH0-B-NA |
GasAlert Max XT II %LEL(F) O2 CO | XT-XW0M-Y-NA | XT-XW0M-B-NA |
GasAlert Max XT II %LEL(F) H2S CO | XT-0WHM-Y-NA | XT-0WHM-B-NA |
GasAlert Max XT II O2 H2S CO | XT-X0HM-Y-NA | XT-X0HM-B-NA |
GasAlertMax XT II 2-Gas Detector | Yellow | Black |
GasAlert Max XT II %LEL(F) O2 | XT-XW00-Y-NA | XT-XW00-B-NA |
GasAlert Max XT II %LEL(F) H2S | XT-0WH0-Y-NA | XT-0WH0-B-NA |
GasAlert Max XT II %LEL(F) CO | XT-0W0M-Y-NA | XT-0W0M-B-NA |
GasAlert Max XT II H2S CO | XT-00HM-Y-NA | XT-00HM-B-NA |
GasAlert Max XT II O2 H2S | XT-X0H0-Y-NA | XT-X0H0-B-NA |
GasAlert Max XT II O2 CO | XT-X00M-Y-NA | XT-X00M-B-NA |
GasAlertMax XT II 1-Gas Detector | Yellow | Black |
GasAlert Max XT II %LEL(F) | XT-0W00-Y-NA | XT-0W00-B-NA |
GasAlert Max XT II O2 | XT-X000-Y-NA | XT-X000-B-NA |
GasAlert Max XT II H2S | XT-00H0-Y-NA | XT-00H0-B-NA |
GasAlert Max XT II CO | XT-000M-Y-NA | XT-000M-B-NA |
*Honeywell Analytics recommends using a combustible (LEL) sensor only when accompanied by an oxygen (O2) sensor. As oxygen is required for the detection of combustible gases, a LEL sensor may not detect combustible hazards in an oxygen deprived environment.
Note: This page lists configurations using filtered LEL sensors only. See the next page for configurations using non-filtered LEL sensors. For more information on filtered and non-filtered LEL sensors, please refer to the Section on Filtered LEL Sensor Information.
GasAlertMax XT II Region Codes |
For orders outside North America, change order number component “-NA” to: |
“-UK” United Kingdom |
“-NA” North America |
“-AU” Australia |
“-CN” China |
“-BR” Brazil |
“-OR” 3 pin UK plug |
“-JP” Japan Ex |
“-OE” others |
Gas Legend | |
%LEL | Combustible (U) |
O2 | Oxygen (X) |
H2S | Hydrogen sulfide (H) |
CO | Carbon monoxide (M) |

MicroDock II. Automatic test and calibration station (see MicroDock II section
for additional information)
Non-filtered combustible (%LEL) sensor configurations for Honeywell BW Max XT II gas detector
GasAlertMax XT II 4-Gas Detector | Yellow | Black |
GasAlert Max XT II %LEL(U) O2 H2S CO | XT-XUHM-Y-NA | XT-XUHM-B-NA |
GasAlertMax XT II 3-Gas Detector | Yellow | Black |
GasAlert Max XT II %LEL(U) O2 H2S | XT-XUH0-Y-NA | XT-XUH0-B-NA |
GasAlert Max XT II %LEL(U) O2 CO | XT-XU0M-Y-NA | XT-XU0M-B-NA |
GasAlert Max XT II %LEL(U) H2S CO | XT-0UHM-Y-NA | XT-0UHM-B-NA |
GasAlertMax XT II 2-Gas Detector | Yellow | Black |
GasAlert Max XT II %LEL(U) O2 | XT-XU00-Y-NA | XT-XU00-B-NA |
GasAlert Max XT II %LEL(U) H2S | XT-0UH0-Y-NA | XT-0UH0-B-NA |
GasAlert Max XT II %LEL(U) CO | XT-0U0M-Y-NA | XT-0U0M-B-NA |
*Honeywell Analytics recommends using a combustible (LEL) sensor only when accompanied by an oxygen (O₂) sensor. As oxygen is required for the detection of combustible gases, a LEL sensor may not detect combustible hazards in an oxygen deprived environment
Note: This page lists configurations using non-filtered LEL sensors only. See the previous page for configurations using filtered LEL sensors. For more information on filtered and non-filtered LEL sensors, see Section on Filtered LEL Sensor Information.
GasAlertMax XT II Region Codes |
For orders outside North America, change order number component “-NA” to: |
“-UK” United Kingdom |
“-NA” North America |
“-AU” Australia |
“-CN” China |
“-BR” Brazil |
“-OR” 3 pin UK plug |
“-JP” Japan Ex |
“-OE” others |
Gas Legend | |
%LEL | Combustible (U) |
O2 | Oxygen (X) |
H2S | Hydrogen sulfide (H) |
CO | Carbon monoxide (M) |
Confined Space Entry Kit for BW GasAlert Max XT II multigas detector
Description | Order Number |
GasAlertMax XT II Deluxe Confined Space Kit | XT-CK-DL |
includes IR Connectivity Kit with Fleet Manager II software, sampling probe, | |
10 ft. / 3 m sampling hose, 3 ft. / 1 m hose, concussion-proof boot, carrying holster, | |
0.5 LPM regulator and carrying case with foam insert. | |
Detector and calibration gas sold separately. | |
Carrying case for GasAlertMax XT II with foam insert | XT-CK-CC |
Detector and calibration gas sold separately |
Carrying & Protective Accessories for BW GasAlert Max XT II multigas detector
Description | Order Number |
Concussion-proof boot with stainless steel alligator-style clip | GA-BXT |
Carrying holster for GasAlertMax XT II and sampling hose | GA-HXT |
Neck strap with safety release | GA-NS-1 |
Extension strap (4 ft./1.2 m) | GA-ES-1 |
Short strap (6 in. / 15.2 cm) | GA-LY-1 |
Chest harness | GA-CH-2 |

Honeywell BW™ Connect IR to BLE Adaptor
Get real-time visibility on your workers’ safety and location without the cost or complexity of wireless gas detectors. With Honeywell BW Connect, it is easy to bring connectivity to your trusted current fleet of BW gas detectors. The below pricing is for the BW Connect adapter. For instructions on how to download and use Safety Communicator, please refer to the BW Connect manual. For pricing on options of software, please contact your local Sales Manager.
Supported Products:
BW MicroClip XL
BW MicroClip X3
BW Max XT II
Note: Safety Suite Real Time license is needed to connect to Systems’ Real Time Monitoring
Description | Order Number |
BW Connect BLE adapter | BW-CONNECT |
Sampling/Testing Equipment and Spares for BW GasAlert Max XT II multigas detector
Description | Order Number |
Auxiliary filter for pump GasAlert Max XTII and Micro 5, kit of 5 | M5-AF-K2 |
Auxiliary filter for pump GasAlert Max XTII and Micro 5, kit of 100 | M5-AF-K2-100 |
Hydrophobic Filter for pump (Thin) GasAlert Max XT II, kit of 5 | XT-RF-H5 |
Hydrophobic Filter for pump (Thin) GasAlert Max XT II, kit of 50 | XT-RF-H50 |
Hydrophobic Filter for pump (Thin) GasAlert Max XT II, kit of 100 | XT-RF-H100 |
Particulate Filter for pump (Thick) GasAlert Max XT II, kit of 5 | GA-PFMAX |
Particulate Filter for pump (Thick) GasAlert Max XT II, kit of 50 | GA-PFMAX-50 |
Particulate Filter for pump (Thick) GasAlert Max XT II, kit of 100 | GA-PFMAX-100 |
Quick connect fitting spares for hoses (kit of 2) | M0931K |
Sampling hose (65 ft. / 19.8 m, 1/8 in. I.D., 1/4 in. O.D.) kit (with connectors and 3 particulate filter) | HOSE1-65 |
Sampling hose (65 ft. / 19.8 m, 1/8 in. I.D., 1/4 in. O.D.) kit, Teflon lined for reactive gases (with connectors and 3 particulate filter) | HOSE2-65 |
Note: For complete list of Sampling & Testing Equipment, please refer to the Sampling Accessories section
Power Supplies for BW GasAlert Max XT II multigas detector
Description | Order Number |
Multi-unit (5) cradle charger | XT-C01-MC5 |
Multi-unit (5) wall outlet power adaptor | GA-PA-1-MC5-NA* |
12-24 Vdc vehicle power adaptor | GA-VPA-1 |
12-24 Vdc direct-wire power adaptor | GA-PA-3 |
Replacement wall outlet power adaptor | GA-PA-1-NA* |
*For regions outside North America replace “-NA” with: “-UK” for United Kingdom , “EU” for Europe and “-AU” for Australia

Datalogging Accessories for BW GasAlert Max XT II multigas detector
Description | Order Number |
IR connectivity kit with Fleet Manager II software | GA-USB1-IR |
Replacement Sensor Screens for BW GasAlert Max XT II multigas detector
Description | Order Number |
Replacement quad sensor screens for GasAlertMax XT II (kit of 2) | XT-SS-1 |
Replacement quad sensor screens for GasAlertMax XT II (kit of 10) | XT-SS-K2 |
Replacement Sensors for BW GasAlert Max XT II multigas detector
Description | Order Number |
Replacement MICROpeL® combustible (LEL) sensor, filtered | SR-W-MP75C |
Replacement MICROpeL® combustible (LEL) sensor, unfiltered | SR-W-MP75 |
Replacement oxygen (O₂) sensor (4-Series) | SR-X2V |
Replacement MICROceL® hydrogen sulfide (H₂S) sensor | SR-H-MC |
Replacement MICROceL® carbon monoxide (CO) sensor | SR-M-MC |
Dummy sensor for combustible (LEL) sensor location | SR-W-MC-DUM |
Dummy sensor for the oxygen sensor location | SR-DUMM1 |
Dummy sensor for toxic sensor locations | SR-TOX-MC-DUM |


IntelliDoX, unmatched performance and customization.
The IntelliDoX instrument management system combines smart docking modules with Safety Suite Device Configurator software to provide automated instrument management, helping drive productivity, reliability and efficiency. Place the detector in the docking module, and it automatically tests the gas detector and sensors while transferring data to the docking station.
(see IntelliDoX section for additional information)

How to Replace the Battery for BW GasAlert Max XT II multigas detector
1. With detector OFF, use No. 1 Phillips screwdriver to loosen retaining screw on pump enclosure (H)
2. Lift pump enclosure (H) so it unhooks from back enclosure (G)
3. Use No. 1 Phillips screwdriver to remove 6 screws from back enclosure (G)
4. Lift back enclosure (G) straight up
5. Lift battery (E) straight up, un-thread wires and disconnect battery wires from the battery connector (P)
6. Connect new battery wires (P), re-thread wires and place new battery on PCB (D)
7. Replace back enclosure (G)
8. Replace 6 screws in back enclosure (G) and hand-tighten until firm
9. Replace pump enclosure (H) and hand-tighten retaining screw until firm
How to Replace the Pump Module for BW GasAlert Max XT II multigas detector
1. With detector OFF, use No. 1 Phillips screwdriver to loosen retaining screw on pump enclosure (H)
2. Lift pump enclosure (H) so it unhooks from back enclosure (G)
3. Use No. 1 Phillips screwdriver to remove 6 screws from back enclosure (G)
4. Lift back enclosure (G) straight up
5. Lift battery straight up and un-thread pump module (F) wires
6. Disconnect hose with connector from the black housing of the pump module (F)
7. Lift pump module (F) straight up and disconnect pump module (F) wires from the pump connector (Q)
8. Connect new pump module wires (Q), re-thread wires and place new pump module (F) on PCB (D)
9. Reconnect hose with connector to the black housing of the pump module (F)
10. Return battery to PCB (D) and replace back enclosure (G)
11. Replace 6 screws in the back enclosure (G) and hand-tighten until firm
12. Replace pump enclosure (H) and hand-tighten retaining screw until firm
Note: Please refer to the instrument’s documentation (shipped with the product or available at www.honeywellanalytics.com) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility.
Honeywell assumes no liability for damages resulting from imprope servicing or maintenance.
Service Parts | Legend | Minimum Service Training Level |
Order Number |
Replacement LCD kit for GasAlertMax XT II | A | Level-1 | XT-LCD-K1 |
Replacement front enclosure (yellow) for GasAlertMax XT II with 6 screws of one type |
B | Level-1 | XT-FC1-1 |
Replacement front enclosure (black) for GasAlertMax XT II with 6 screws of one type |
B | Level-1 | XT-FC1B-1 |
Replacement combustible sensor, see previous page | C | Level-1 | |
Replacement main PCB with screws for GasAlertMax XT II | D | Level-2 | XT-MPCB2 |
Replacement battery kit for GasAlertMax XT II | E | Level-1 | XT-BAT-K1 |
Replacement pump kit for GasAlertMax XT II | F | Level-1 | XT-RPUMP-K1 |
Replacement back enclosure (yellow) with screws for GasAlertMax XT II | G | Level-1 | XT-BC1 |
Replacement back enclosure (black) with screws for GasAlertMax XT II | G | Level-1 | XT-BC1B |
Replacement pump enclosure (yellow) with screw for GasAlertMax XT II | H | None | XT-PC1 |
Replacement pump enclosure (black) with screw for GasAlertMax XT II | H | None | XT-PC1B |
Replacement particulate pump filter (thick), see previous page | I | None | |
Replacement hydrophobic pump filter (thin), see previous page | J | None | |
Replacement toxic and oxygen sensors, see previous page | K,L,M | Level-1 | |
Replacement sensor screen, see previous page | N | Level-1 | |
Replacement sensor enclosure with screw (yellow) with screw | O | None | XT-SC1 |
Replacement sensor enclosure with screw (black) with screw | O | None | XT-SC1B |
Replacement alligator clip with screw | None | XT-AG-1 | |
Replacement screw kit for GasAlertMax XT II – PCB screws (one type) and back case screws (one type) |
None | XT-SCREW-K1 | |
Replacement vibration motor | Level-1 | GA-VM-2 |
Note: For service and trainings, please refer to the Training and Service Information sections
How to Replace a Sensor for BW GasAlert Max XT II multigas detector
1. With detector OFF, use No. 1 Phillips screwdriver to loosen retaining screw on pump enclosure (H)
2. Lift pump enclosure (H) so it unhooks from back enclosure (G)
3. Use No. 1 Phillips screwdriver to remove 6 screws from back enclosure (G)
4. Lift back enclosure (G) straight up
5. Use No. 1 Phillips screwdriver to remove 2 screws from back of PCB (D)
6. Lift PCB (D) together with battery and sensors straight up
7. Remove sensor (C, K, L) by sliding out or sensor (M) by pulling straight up from PCB (D)
8. Insert new sensor (C, K, L, M) into PCB (D)
9. Replace PCB (D) and 2 screws and hand-tighten until firm
10. Replace back enclosure (G)
11. Replace 6 screws in the back enclosure (G) and hand-tighten until firm
12. Replace pump enclosure (H) and hand-tighten retaining screw until firm
How to Replace the Sensor Screen for BW GasAlert Max XT II multigas detector
1. With detector OFF, use No. 1 Phillips screwdriver to loosen retaining screw on pump enclosure (H)
2. Lift pump enclosure (H) so it unhooks from back enclosure (G)
3. Use No. 1 Phillips screwdriver to remove 6 screws from back enclosure (G)
4. Lift back enclosure (G) straight up
5. Use No. 1 Phillips screwdriver to remove 2 screws from back of PCB (D)
6. Lift PCB (D) together with battery and sensors straight up
7. Remove sensor screen (N) from front enclosure (B) by pulling straight up
8. Insert new sensor screen (N) into front enclosure (B)
9. Replace PCB (D) and 2 screws and hand-tighten until firm
10. Replace back enclosure (G)
11. Replace 6 screws in the back enclosure (G) and hand-tighten until firm
12. Replace pump enclosure (H) and hand-tighten retaining screw until firm
Note: Please refer to the instrument’s documentation (shipped with the product or available at www.honeywellanalytics.com) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility.
Honeywell assumes no liability for damages resulting from imprope servicing or maintenance.
Introduction and Instruction videos for BW GasAlert Max XT II multigas detector
Reviews