BW Honeywell GasAlertQuattro Multigas detector for LEL O2 CO H2S (Large LCD type), Visual auditing, easy compliance. The most popular PN are: QT-XWHM-R-Y-OE và QT-XWHM-R-Y-NA
Rugged and reliable, the GasAlertQuattro four-gas detector combines a comprehensive range of features with simple one-button operation. With flexible power options, the GasAlertQuattro is always ready. The graphic LCD displays easy to identify icons that indicate operational information, such as bump test and calibration status for simplified onsite auditing. IntelliFlash™ provides continuous visual confirmation of detector operation and compliance. Suited to a wide range of industrial applications including confined space entry, the GasAlertQuattro is fully compatible with BW’s MicroDock II automatic test and calibration system
Meets ACGIH 1 ppm H2S TWA recommendations.
Visit www.honeywellanalytics.com to download the latest Fleet Manager II update.
Standard Package Contents:
• GasAlertQuattro detector
• Rechargeable battery pack or alkaline pack with three AA batteries
• Charger wall plug (with rechargeable battery option)
• Calibration cap and hose
• Reversible screwdriver
• Manual
General Specification for BW Honeywell GasAlertQuattro
Gas Legend
%LEL
Combustible (W)
O2
Oxygen (X)
H2S
Hydrogen sulfide (H)
CO
Carbon monoxide (M)
Filtered combustible (%LEL) sensor configurations – Alkaline Version for BW Honeywell GasAlertQuattro
GasAlertQuattro 4-Gas Detector
Order Number
GasAlert Quattro %LEL(F) O2 H2S CO
QT-XWHM-A-Y-NA
GasAlertQuattro 3-Gas Detector
Order Number
GasAlert Quattro %LEL(F) O2 H2S
QT-XWH0-A-Y-NA
GasAlert Quattro %LEL(F) O2 CO
QT-XW0M-A-Y-NA
GasAlert Quattro %LEL(F) H2S CO
QT-0WHM-A-Y-NA
GasAlert Quattro O2 H2S CO
QT-X0HM-A-Y-NA
GasAlertQuattro 2-Gas Detector
Order Number
GasAlert Quattro %LEL(F) O2
QT-XW00-A-Y-NA
GasAlert Quattro %LEL(F) H2S
QT-0WH0-A-Y-NA
GasAlert Quattro %LEL(F) CO
QT-0W0M-A-Y-NA
GasAlert Quattro H2S CO
QT-00HM-A-Y-NA
GasAlert Quattro O2 H2S
QT-X0H0-A-Y-NA
GasAlert Quattro O2 CO
QT-X00M-A-Y-NA
GasAlertQuattro 1-Gas Detector
Order Number
GasAlert Quattro %LEL(F)
QT-0W00-A-Y-NA
GasAlert Quattro O2
QT-X000-A-Y-NA
GasAlert Quattro H2S
QT-00H0-A-Y-NA
GasAlert Quattro CO
QT-000M-A-Y-NA
*Honeywell Analytics recommends using a combustible (LEL) sensor only when accompanied by an oxygen (O2) sensor. As oxygen is required for the detection of combustible gases, a LEL sensor may not detect combustible hazards in an oxygen deprived environment.
Note: This page lists configurations using filtered LEL sensors only. See the next page for configurations using non-filtered LEL sensors. For more information on filtered and non-filtered LEL sensors, please refer to the Section on Filtered LEL Sensor Information.
GasAlertQuattro Region Codes
For orders outside North America, change order number component “-NA” to:
“-UK” United Kingdom
“-NA” North America
“-AU” Australia
“-CN” China
“-BR” Brazil
“-OR” 3 pin UK plug
“-OE” others
Filtered combustible (%LEL) sensor configurations – Rechargeable Version for BW Honeywell GasAlertQuattro
GasAlertQuattro 4-Gas Detector
Order Number
GasAlert Quattro %LEL(F) O2 H2S CO
QT-XWHM-R-Y-NA
GasAlertQuattro 3-Gas Detector
Order Number
GasAlert Quattro %LEL(F) O2 H2S
QT-XWH0-R-Y-NA
GasAlert Quattro %LEL(F) O2 CO
QT-XW0M-R-Y-NA
GasAlert Quattro %LEL(F) H2S CO
QT-0WHM-R-Y-NA
GasAlert Quattro O2 H2S CO
QT-X0HM-R-Y-NA
GasAlertQuattro 2-Gas Detector
Order Number
GasAlert Quattro %LEL(F) O2
QT-XW00-R-Y-NA
GasAlert Quattro %LEL(F) H2S
QT-0WH0-R-Y-NA
GasAlert Quattro %LEL(F) CO
QT-0W0M-R-Y-NA
GasAlert Quattro H2S CO
QT-00HM-R-Y-NA
GasAlert Quattro O2 H2S
QT-X0H0-R-Y-NA
GasAlert Quattro O2 CO
QT-X00M-R-Y-NA
GasAlertQuattro 1-Gas Detector
Order Number
GasAlert Quattro %LEL(F)
QT-0W00-R-Y-NA
GasAlert Quattro O2
QT-X000-R-Y-NA
GasAlert Quattro H2S
QT-00H0-R-Y-NA
GasAlert Quattro CO
QT-000M-R-Y-NA
*Honeywell Analytics recommends using a combustible (LEL) sensor only when accompanied by an oxygen (O2) sensor. As oxygen is required for the detection of combustible gases, a LEL sensor may not detect combustible hazards in an oxygen deprived environment.
Note: This page lists configurations using filtered LEL sensors only. See the next page for configurations using non-filtered LEL sensors. For more information on filtered and non-filtered LEL sensors, please refer to the Section on Filtered LEL Sensor Information.
GasAlertQuattro Region Codes
For orders outside North America, change order number component “-NA” to:
“-UK” United Kingdom
“-NA” North America
“-AU” Australia
“-CN” China
“-BR” Brazil
“-OR” 3 pin UK plug
“-OE” others
Non-filtered combustible (%LEL) sensor configurations – Alkaline Version for BW Honeywell GasAlert Quattro
GasAlertQuattro 4-Gas Detector
Order Number
GasAlert Quattro %LEL(U) O2 H2S CO
QT-XUHM-A-Y-NA
GasAlertQuattro 3-Gas Detector
Order Number
GasAlert Quattro %LEL(U) O2 H2S
QT-XUH0-A-Y-NA
GasAlert Quattro %LEL(U) O2 CO
QT-XU0M-A-Y-NA
GasAlert Quattro %LEL(U) H2S CO
QT-0UHM-A-Y-NA*
GasAlertQuattro 2-Gas Detector
Order Number
GasAlert Quattro %LEL(U) O2
QT-XU00-A-Y-NA
GasAlert Quattro %LEL(U) H2S
QT-0UH0-A-Y-NA
GasAlert Quattro %LEL(U) CO
QT-0U0M-A-Y-NA
*Honeywell Analytics recommends using a combustible (LEL) sensor only when accompanied by an oxygen (O2) sensor. As oxygen is required for the detection of combustible gases, a LEL sensor may not detect combustible hazards in an oxygen deprived environment.
Note: This page lists configurations using non-filtered LEL sensors only. See the previous page for configurations using filtered LEL sensors. For more information on filtered and non-filtered LEL sensors, see Section on Filtered LEL Sensor Information.
GasAlertQuattro Region Codes
For orders outside North America, change order number component “-NA” to:
“-UK” United Kingdom
“-NA” North America
“-AU” Australia
“-CN” China
“-BR” Brazil
“-OR” 3 pin UK plug
“-OE” others
Gas Legend
%LEL
Combustible (U)
O2
Oxygen (X)
H2S
Hydrogen sulfide (H)
CO
Carbon monoxide (M)
Non-filtered combustible (%LEL) sensor configurations – Rechargeable Version for BW Honeywell GasAlert Quattro
GasAlertQuattro 4-Gas Detector
Order Number
GasAlert Quattro %LEL(U) O2 H2S CO
QT-XUHM-R-Y-NA
GasAlertQuattro 3-Gas Detector
Order Number
GasAlert Quattro %LEL(U) O2 H2S
QT-XUH0-R-Y-NA
GasAlert Quattro %LEL(U) O2 CO
QT-XU0M-R-Y-NA
GasAlert Quattro %LEL(U) H2S CO
QT-0UHM-R-Y-NA
GasAlertQuattro 2-Gas Detector
Order Number
GasAlert Quattro %LEL(U) O2
QT-XU00-R-Y-NA
GasAlert Quattro %LEL(U) H2S
QT-0UH0-R-Y-NA
GasAlert Quattro %LEL(U) CO
QT-0U0M-R-Y-NA
*Honeywell Analytics recommends using a combustible (LEL) sensor only when accompanied by an oxygen (O2) sensor. As oxygen is required for the detection of combustible gases, an LEL sensor may not detect combustible hazards in an oxygen deprived environment.
Note: This page lists configurations using non-filtered LEL sensors only. See the previous page for configurations using filtered LEL sensors. For more information on filtered and non-filtered LEL sensors, see Section on Filtered LEL Sensor Information.
GasAlertQuattro Region Codes
For orders outside North America, change order number component “-NA” to:
“-UK” United Kingdom
“-NA” North America
“-AU” Australia
“-CN” China
“-BR” Brazil
“-OR” 3 pin UK plug
“-OE” others
Gas Legend
%LEL
Combustible (U)
O2
Oxygen (X)
H2S
Hydrogen sulfide (H)
CO
Carbon monoxide (M)
BW Honeywell GasAlert Quattro’s Confined Space Entry Kit
Description
Order Number
GasAlertQuattro Deluxe Confined Space Kit – includes manual aspirator kit, IR Connectivity
QT-CK-DL
Kit with Fleet Manager II software, sampling probe, carrying holster, auxiliary filter kit, calibration cap
with 1 ft. / 0.3 m hose, 0.5 LPM regulator and carrying case with foam insert.
Detector and calibration gas sold separately.
Carrying case for GasAlertQuattro with foam insert
QT-CK-CC
Detector and calibration gas sold separately
Carrying & Protective Accessories for Honeywell BW GasAlert Quattro
Description
Order Number
Concussion Proof Boot GasAlertQuattro
GA-BQT
Carrying Holster GasAlertQuattro
GA-HQT
Auxiliary filter (LCD protector) – includes five filters
QT-AF-K1
Replacement auxiliary filter for use with QT-AF-K1 (kit of 10)
QT-SS-AF-K1
Vehicle attachment (compatible with single T-pattern or 4-hole AMPS mounting system)
QT-VMB-1
Neck strap with safety release
GA-NS-1
Short strap (6 in./15.2 cm)
GA-LY-1
Extension strap (4 ft./1.2 m)
GA-ES-1
Chest harness
GA-CH-2
Carrying & Protective Accessories for Honeywell BW GasAlert Quattro
BW Quattro’s Sampling & Testing Equipment
Description
Order Number
Manual aspirator pump kit with probe (0.3 m / 1 ft.) for GA Quattro
QT-AS01
Sample probe with hydrophobic and particulate filters
GA-PROB1-1
Filter and gasket replacements for sample probe (GA-PROB1-1)
GA-PROB-FIL-K1
Metallic sintered particulate filter
GA-MFILTER
Replacement Airstone Water/Particulate Filter for Sampling Hoses (kit of 4)
D4-PF-1
Sampling float
GA-FLOAT
Replacement test cap and hose
QT-TC-1
Note: For complete list of Sampling & Testing Equipment, please refer to the Sampling Accessories section
BW Quattro’s Power Supplies and Spares
Description
Order Number
Rechargeable battery pack, yellow
QT-BAT-R01
Rechargeable battery pack, black
QT-BAT-R01B
Alkaline battery pack with batteries, yellow
QT-BAT-A01
Alkaline battery pack with batteries, black
QT-BAT-A01B
Multi-unit (5) cradle charger
QT-C01-MC5
Multi-unit (5) wall outlet power adaptor
GA-PA-1-MC5-NA*
12-24 Vdc vehicle power adaptor
GA-VPA-1
12-24 Vdc direct-wire power adaptor
GA-PA-3
Replacement wall outlet power adaptor
GA-PA-1-NA*
*For regions outside North America replace “-NA” with: “-UK” for United Kingdom , “-EU” for Europe and “-AU” for Australia
BW Quattro’s Power Supplies and Spares
Datalogging Accessories for Honeywell BW GasAlertQuattro Portable gas detector
Description
Order Number
IR connectivity kit with Fleet Manager II software
GA-USB1-IR
GasAlertQuattro Portable gas detector’s Replacement Sensor Screens
Description
Order Number
Replacement quad sensor screen (kit of 2)
QT-SS
Replacement quad sensor screen (kit of 10)
QT-SS-K1
GasAlertQuattro Portable gas detector’s Replacement Sensors
Dummy sensor for one oxygen (O2), hydrogen sulfide (H2S) or carbon monoxide (CO) location
SR-DUMM1
Dummy sensor for the combustible (LEL) location
SR-DUMM2
Datalogging Accessories, Replacement Sensor Screens, Replacement Sensors for BW GasAlertQuattroHoneywell BW GasAlertQuattro Service parts
Service Parts
Legend
Minimum Service Training Level
Order Number
Replacement screw kit (kit of 40 screws) – back case screws (1 type: #4-40 x
7/16”); PCB screws (1 type: #2-56 x 1/4”)
A
None
QT-SCREW-K1
Replacement back enclosure (yellow) with 6 screws of one type, 2 PCB screws
of one type and alligator clip
B
Level-1
QT-BC1
Replacement back enclosure (black) with 6 screws of one type, 2 PCB screws
of one type and alligator clip
B
Level-1
QT-BC1B
Replacement sensors, see previous page
C,D
Level-1
Replacement main PCB and sensor PCB kit
E
Level-2
QT-PCB-K1
Replacement sensor screens, see previous page
F
Level-1
Replacement front enclosure (yellow) with 6 screws of one type and 2 PCB screws of one type
G
Level-1
QT-FC1
Replacement front enclosure (black) with 6 screws of one type and 2 PCB
screws of one type
G
Level-1
QT-FC1B
Replacement sensors, see previous page
H,I
Level-1
Replacement LCD kit
J
Level-1
QT-LCD-K1
Replacement battery pack, see previous pages
K
Level-1
Replacement vibration motor
Level-1
GA-VM-2
$22.00
Replacement alligator-style clip (stainless steel with screw)
None
XT-AG-1
Note: For service and trainings, please refer to the Training and Service Information sections
How to Replace a Sensor
1. With detector OFF, remove battery pack from back of instrument
2. Use No. 1 Phillips screwdriver to remove 6 screws from back enclosure (B)
3. Lift front enclosure (G) straight up
4. Remove sensor (C, D, H, I) from PCB (C) by pulling straight up
5. Insert new sensor (C, D, H, I) into socket
6. Replace front enclosure (G)
7. Replace 6 screws in back enclosure (B) and hand-tighten until firm
How to Replace the Sensor Screen
1. With detector OFF, remove battery pack from back of instrument
2. Use No. 1 Phillips screwdriver to remove 6 screws from back enclosure (B)
3. Lift front enclosure (G) straight up
4. Remove sensor screen (F) from front enclosure (G) by pulling straight up
5. Insert new sensor screen (F) into front enclosure (G)
6. Replace front enclosure (G)
7. Replace 6 screws in back enclosure (B) and hand-tighten until firm
How to Replace the Alkaline Batteries in the Battery Pack
1. With detector OFF, remove battery pack from back of instrument
2. On battery pack, pull on tab (L) until ejector bar (M) releases from the ejector bar holder
3. Pull ejector bar (M) straight up (onside opposite of tab) until batteries dislocate from battery pack
4. Insert new batteries, one by one, inserting positive (+) end first
5. Important: push the ejector bar (M) into the lever holder until fully secured*
6. Insert battery pack into detector
*Failure to perform step 5 properly could result in damage to the batteries, battery pack and/or detector
Note: Please refer to the instrument’s documentation (shipped with the product or available at www.honeywellanalytics.com) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility. Honeywell assumes no liability for damages resulting from imprope servicing or maintenance
Introduction videos for Honeywell GasAlertQuattro
Reviews
There are no reviews yet.
Be the first to review “BW Honeywell GasAlertQuattro Multigas detector for LEL O2 CO H2S (Large LCD type)” Cancel reply
Reviews
There are no reviews yet.