Description
BW Honeywell GasAlertMicroClip XL Multi-Gas (1–4) Detector H2S, CO, O2, LEL, The Multi-gas made simple, Vietnam Order number: MCXL-XWHM-Y-OE
The easy to wear, slim and compact BW Honeywell GasAlertMicroClip XL provides affordable protection from atmospheric gas hazards and extended battery life, especially in cold weather. The GasAlertMicroClip XL features visual compliance at a glance with the flashing, green IntelliFlash™. Easy one-button operation reduces training time and lets workers focus on at hand. For simple, cost-effective management of your records, calibration and bump testing, choose BW’s MicroDock II and IntelliDox automatic test and calibration system and Fleet Manager II software.
Meets ACGIH 1 ppm H2S TWA recommendations.
Standard Package Contents
- Detector complete with specified sensor(s), stainless steel alligator clip and concussion-proof housing
- Rechargeable battery
- Wall outlet charging adaptor
- Calibration/test cap and hose
- Manual
General Specifications of BW Honeywell GasAlertMicroClip XL

Filtered combustible (%LEL) sensor configurations
GasAlertMicroClip XL 4-Gas Detector | Yellow Order Number | Black Order Number |
GasAlert MicroClip XL %LEL(F) O2 H2S CO | MCXL-XWHM-Y-NA | MCXL-XWHM-B-NA |
GasAlertMicroClip XL 3-Gas Detector | Yellow Order Number | Black Order Number |
GasAlert MicroClip XL %LEL(F) O2 H2S | MCXL-XWH0-Y-NA | MCXL-XWH0-B-NA |
GasAlert MicroClip XL %LEL(F) O2 CO | MCXL-XW0M-Y-NA | MCXL-XW0M-B-NA |
GasAlert MicroClip XL %LEL(F) H2S CO | MCXL-0WHM-Y-NA | MCXL-0WHM-B-NA |
GasAlert MicroClip XL O2 H2S CO | MCXL-X0HM-Y-NA | MCXL-X0HM-B-NA |
GasAlertMicroClip XL 2-Gas Detector | Yellow Order Number | Black Order Number |
GasAlert MicroClip XL %LEL(F) O2 | MCXL-XW00-Y-NA | MCXL-XW00-B-NA |
GasAlert MicroClip XL %LEL(F) H2S | MCXL-0WH0-Y-NA | MCXL-0WH0-B-NA |
GasAlert MicroClip XL %LEL(F) CO | MCXL-0W0M-Y-NA | MCXL-0W0M-B-NA |
GasAlert MicroClip XL H2S CO | MCXL-00HM-Y-NA | MCXL-00HM-B-NA |
GasAlert MicroClip XL O2 H2S | MCXL-X0H0-Y-NA | MCXL-X0H0-B-NA |
GasAlert MicroClip XL O2 CO | MCXL-X00M-Y-NA | MCXL-X00M-B-NA |
GasAlertMicroClip XL 1-Gas Detector | Yellow Order Number | Black Order Number |
GasAlert MicroClip XL O2 | MCXL-X000-Y-NA | MCXL-X000-B-NA |
GasAlert MicroClip XL H2S | MCXL-00H0-Y-NA | MCXL-00H0-B-NA |
GasAlert MicroClip XL CO | MCXL-000M-Y-NA | MCXL-000M-B-NA |
*Honeywell Analytics recommends using a combustible (LEL) sensor only when accompanied by an oxygen (O₂) sensor. As oxygen is required for the detection of combustible gases, a LEL sensor may not detect combustible hazards in an oxygen deprived environment.
Note: This page lists configurations using filtered LEL sensors only. See the next page for configurations using non-filtered LEL sensors. For more information on filtered and non-filtered LEL sensors, please refer to the Section on Filtered LEL Sensor Information.
GasAlertMicroClip XL Region Codes
For orders outside North America, change order number component “-NA” to:
“-UK” United Kingdom
“-NA” North America
“-AU” Australia
“-CN” China
“-BR” Brazil
“-OR” 3 pin UK plug
“-OE” others, Example: MCXL-XWHM-Y-OE for Vietnam market
Gas Legend | |
%LEL | Combustible (W) |
O2 | Oxygen (X) |
H2S | Hydrogen sulfide (H) |
CO | Carbon monoxide (M) |
Non-filtered combustible (%LEL) sensor configurations
GasAlertMicroClip XL 4-Gas Detector | Yellow Order Number | Black Order Number |
GasAlert MicroClip XL %LEL(U) O₂ H₂S CO | MCXL-XUHM-Y-NA | MCXL-XUHM-B-NA |
GasAlertMicroClip XL 3-Gas Detector | ||
GasAlert MicroClip XL %LEL(U) O2 H2S | MCXL-XUH0-Y-NA | MCXL-XUH0-B-NA |
GasAlert MicroClip XL %LEL(U) O2 CO | MCXL-XU0M-Y-NA | MCXL-XU0M-B-NA |
GasAlert MicroClip XL %LEL(U) H2S CO | MCXL-0UHM-Y-NA | MCXL-0UHM-B-NA |
GasAlertMicroClip XL 2-Gas Detector | ||
GasAlert MicroClip XL %LEL(U) O₂ | MCXL-XU00-Y-NA | MCXL-XU00-B-NA |
GasAlert MicroClip XL %LEL(U) H₂S | MCXL-0UH0-Y-NA | MCXL-0UH0-B-NA |
GasAlert MicroClip XL %LEL(U) CO | MCXL-0U0M-Y-NA | MCXL-0U0M-B-NA |
*Honeywell Analytics recommends using a combustible (LEL) sensor only when accompanied by an oxygen (O2) sensor. As oxygen is required for the detection of combustible gases, an LEL sensor may not detect combustible hazards in an oxygen deprived environment.
Note: This page lists configurations using non-filtered LEL sensors only. See the previous page for configurations using filtered LEL sensors. For more information on filtered and non-filtered LEL sensors, see Section on Filtered LEL Sensor Information.
Gas Legend | |
%LEL | Combustible (U) |
O2 | Oxygen (X) |
H2S | Hydrogen sulfide (H) |
CO | Carbon monoxide (M) |
Confined Space Entry Kit for BW Honeywell GasAlertMicroClip XL
- Confined Space Kit GasAlert MicroClip XL and X3: Part number: MC-CK-DL
GasAlertMicroClip XL deluxe confined space kit – includes manual aspirator kit, IR connectivity kit with Fleet Manager II software, calibration cap with 1 ft. / 0.3 m hose, 0.5 LPM regulator, sampling probe, leather carrying case, auxiliary filter and carrying case with foam insert.
Detector and calibration gas sold separately.
- Carrying Case for GasAlert MicroClip XL and X3 with foam and lid insert: Part number: MC-CK-CC
Detector and calibration gas sold separately
Carrying & Protective Accessories for GasAlert MicroClip XL
- Neck strap with safety release: GA-NS-1
- Short strap (6 in./15.2 cm): GA-LY-1
- Extension strap (4 ft./1.2 m) :GA-ES-1
- Chest harness: GA-CH-2
- Black leather and PVC carrying holster GasAlert MicroClip XL and X3: MC2-LC-1
- Auxiliary Filter Kit (complete with filter adaptor and 5 filters): MC-AF-K1
- Auxiliary Filter Adaptor (no filter): MC-AF-1
- Auxiliary Filter Filter replacement for adaptor (kit of 10): MC-SS-AF-K1

Honeywell BW™ Connect IR to BLE Adaptor, Order Number: BW-CONNECT
Get real-time visibility on your workers’ safety and location without the cost or complexity of wireless gas detectors. With Honeywell BW Connect, it is easy to bring connectivity to your trusted current fleet of BW gas detectors.
The below pricing is for the BW Connect adapter. For instructions on how to download and use Safety Communicator, please refer to the BW Connect manual. For pricing on options of software, please contact your local Sales Manager.
Supported Products: |
BW MicroClip XL |
BW MicroClip X3 |
BW Max XT II |
Note: Safety Suite Real Time license is needed to connect to Systems’ Real Time Monitoring
Sampling & Testing Equipment for Honeywell BW GasAlert MicroClip XL
- Manual Aspirator Pump Kit with probe (1 ft./0.3 m), PN: MC-AS01
- Test cap and hose (1 ft/0.3 m) replacement, PN: MC-TC-1
Power Supplies and Spares for Honeywell BW GasAlert MicroClip XL
Description | Order Number |
Multi-unit (5) cradle charger | MC2-C01-MC5 |
Multi-unit (5) wall outlet power adaptor | GA-PA-1-MC5-NA* |
Vehicle 12-24VDC power adaptor with plug | GA-VPA-1 |
Vehicle 12-24VDC direct-wire power adaptor | GA-PA-3 |
Replacement wall outlet power adaptor | GA-PA-1-NA* |
*For regions outside North America replace “-NA” with: “-UK” for United Kingdom , “-EU” for Europe and “-AU” for Australia. For Vietnam market, it is “-OE”
Datalogging Accessories
- IR connectivity kit with Fleet Manager II software, PN: GA-USB1-IR

Replacement Sensors and Sensor Screens for MCXL gas detector
- Replacement quad sensor screen filter for GasAlertMicroClip XL/X3 (kit of 2) MC2-SS
- Replacement quad sensor screen filter for GasAlertMicroClip XL/X3 (kit of 10) MC2-SS-K1
- Replacement MICROpeL® combustible (LEL) sensor, filtered SR-W-MP75C
- Replacement MICROpeL® combustible (LEL) sensor, unfiltered SR-W-MP75
- Replacement oxygen (O2) sensor SR-X2V
- Replacement MICROceL® hydrogen sulfide (H2S) sensor SR-H-MC
- Replacement MICROceL® carbon monoxide (CO) sensor SR-M-MC
- Dummy sensor for combustible (LEL) sensor location SR-W-MC-DUM
- Dummy sensor for the oxygen sensor location SR-DUMM1
- Dummy sensor for toxic sensor locations SR-TOX-MC-DUM

IntelliDoX, unmatched performance and customization.
The IntelliDoX instrument management system combines smart docking modules with Safety Suite Device Configurator software to provide automated instrument management, helping drive productivity, reliability and efficiency. Place the detector in the docking module, and it automatically tests the gas detector and sensors while transferring data to the docking station.

Service Parts for BW Honeywell GasAlertMicroClip XL gas detector

Service Parts | Legend | Minimum Service Training Level | Order Number |
Replacement LCD kit for GasAlertMicroClip XL | A | Level-1 | MC-LCD-K1 |
Replacement front enclosure (yellow) for GasAlertMicroClip XL with 6 screws of | B | Level-1 | MCXL-FC1 |
Replacement front enclosure (black) for GasAlertMicroClip XL with 6 screws of | B | Level-1 | MCXL-FC1B |
Replacement combustible sensor, see previous page | C | Level-1 | |
Replacement main PCB with battery and screws | D | Level-2 | MCXL-MPCB1 |
Replacement back enclosure (yellow) with screws and alligator clip | E | Level-1 | MCXL-BC1 |
Replacement back enclosure (black) with screws and alligator clip | E | Level-1 | MCXL-BC1B |
Replacement screws (kit of 20) – PCB Screws
(one type, same as back case screws); back case screws (one type, same as PCB screws) |
F |
None |
MC-SCREW-K1 |
Replacement toxic and oxygen sensors, see previous page | G,H,I | Level-1 | |
Replacement sensor screen, see previous page | J | Level-1 | |
Oxygen (O2) sensor PCB including flex cable | K | Level-1 | MC2-FPCB1 |
Replacement vibration motor | Level-1 | GA-VM-2 |