Marsen: BAL-2000 Level measuring system for Draft and ballast tank / Pressure type
Model: BAL-2000/ Pressure type
General introduction
The pressure-type ballast and draft level measurement system is designed to measure the level of ballast tanks, tangle levels, and fuel oil tanks of ships. The system uses sensors that measure the level of electrolysic pressure and are used to measure levels of different types of tanks.
Characteristics and features
- Easy installation and replacement of sensors
- Reasonable price
- Simple structure
- Built-in LCD monitor
- High-precision measurement results
- Good stability
Application
- Remote monitoring of ballast water tanks
- Tangled remote monitoring
- Remote fuel oil tank tracking
Structure and principle of operation of the system
The BAL-2000 includes pressure gauge sensors, control cabinets, display sets and isolaters.
The pressure type sensor converts to detect the pressure change and gives the tank level alarm result as a 4-20mA signal when the liquid pressure acts on it.
Technical Specifications
Sensor type | Soy voltage pressure type |
Measuring range | 0 – 35m (on request) |
Accuracy | ± 0.2% of F.S. |
Feeds | AC 110/220, 50/60 Hz, /DC 12-30V |
Output signal | 4-20mA |
Explosion room certification | Ex ia IIC T4 |
Temperature | -20 – 100 ◦C |
IP protection level | IP56 Control Cabinet (IP68 for Case), IP Sensor 68 |
System structure