GasAlert Extreme ETO GAXT-E-DL

BW GasAlert Extreme Single Gas detector, Gas Type Optionable

The GasAlert Extreme single gas detector measures one of the following toxic gases: Hydrogen Sulfide (H2S) / Sulfur Dioxide (SO2) / Hydrogen Cyanide (HCN) / Carbon Monoxide (CO) / Chlorine (CI2) / Nitrogen Dioxide (NO2) / Ammonia (NH3) / Phosphine (PH3) / Ethylene Oxide (ETO) / Chlorine Dioxide (ClO2) / Ozone (O3) / Nitric Oxide (NO) / Oxygen (O2)

Popular GasAlert Extreme Single Gauge Codes

See more full GasAlert Extreme codes here

Compact, solid, gasalert extreme single-gas detector designed by BW with the most advanced RFI protection technology today. With IP66/67 waterproof when completely submerged below 3ft.GasAlert Extreme also has anti-shock, anti-vibration features. Provide readiness to put into use, simply clamp the device to the belt, bag, hard hat for better protection.

With backlighting, the large LCD monitor displays the gas concentration in real time and the condition of the device at all times. The comprehensive self-check feature checks the sensor, circuit, battery comprehensive, and activates the alert image sound yourself every time you start the device. The machine will clearly report on current hazardous gases under the low, high, TWA and STEL warning modes. Write the TWA, STEL, and peak values of exposure that can be displayed in the command line.

GasAlert Extreme single gas detector provides cost of ownership with special advantages. Includes automatic calibration, 1 lithium battery for 3 years, available in local stores, one control button. Each of these features reduces your training and maintenance costs. Operated by an advanced micro processor and electrolynizing sensor, the GasAlert Extreme gas detector is equipped with high volume sound alerts, visual images.

GasAlert Extreme Single Gas Meter Features

  • All GasAlert Extreme is covered with anti-vibration rubber, impact
  • The LCD monitor continuously displays the gas concentration in real time with a backlight in low light conditions (automatic mode); in alert mode (automatic) and on-demand
  • IP66/67 waterproof design when submerged up to 3 ft deep
  • Warning mode with 85 dB volume horn and LED indicator
  • Battery durability up to 3 years
  • Built-in vibration alerts available
  • Equipped with additional features or sensor replacement
  • Simple zero process and calibration
  • Displays the peak value on the command, in ppm or % volume
  • Record and display TWA values to assess hazards from cumulative exposure and assist in complying with regulations and regulations
  • Safety classification by US UL, Canadian standard, certified in Australia
  • Comprehensive self-testing features of: sensor, battery, full circuit and audio/image
  • Small and light size
  • Adjustable warning points : LOW, HIGH, TWA, STEL
  • Includes clips for putting on shirts, shutter caps and sampling tubes, batteries, local language instruction

Extreme GasAlert Specifications

GasAlert for Measuring Range TWA Alarm STEL Alarm Low Alarm High Alarm Relative Humidity non-condensing Operating Temperature
Hydrogen Sulfide (H2S) 0-100 ppm 10 ppm 15 ppm 10 ppm 15 ppm 15-90 -40 to +50 °C
-40 to +122 °F
Sulfur Dioxide (SO2) 0-100 ppm 2 ppm 5 ppm 2 ppm 5 ppm 15-90  
Hydrogen Cyanide (HCN) 0-30.0 ppm 4.7 ppm 10.0 ppm 4.7 ppm 10.0 ppm 15-95  
Carbon Monoxide (CO) 0-999 ppm 35 ppm 200 ppm 35 ppm 200 ppm 15-90 -30 to +50 °C
-22 to +122 °F
Chlorine (CI2) 0-50.0 ppm 0.5 ppm 1.0 ppm 0.5 ppm 1.0 ppm 10-95 -20 to +50 °C
-4 to +122 °F
Nitrogen Dioxide (NO2) 0-99.9 ppm 2.0 ppm 5.0 ppm 2.0 ppm 5.0 ppm 15-90  
Ammonia (NH3) 0-100 ppm 25 ppm 35 ppm 25 ppm 50 ppm 15-90  
Phosphine (PH3) 0-5.0 ppm 0.3 ppm 1.0 ppm 0.3 ppm 1.0 ppm 15-90  
Ethylene Oxide (ETO) 0-100 ppm 1 ppm 5 ppm 1 ppm 5 ppm 15-90  
Chlorine Dioxide (ClO2) 0-1 ppm 0.1 ppm 0.3 ppm 0.1 ppm 0.3 ppm 15-95  
Ozone (O3) 0-1 ppm 0.1 ppm 0.1 ppm 0.1 ppm 0.2 ppm 15-90  
Nitric Oxide (NO) 0-250 ppm 25 ppm 25 ppm 25 ppm 25 ppm 15-90  
Oxygen (O2) 0-30.0% N/a N/a 19.5 % 22.5% 0-99  
Auto zero Yes
Calibration Automatic
Backlight Low light (auto); alarm condition (auto); on demand
Full function self-test Verifies integrity of sensor, circuitry and battery; audible/visual alarms
Sensor Plug-in, electrochemical cell (temperature compensated)
Indicators And Alarms Clearly advises alarm levels both visually and audibly
Visual alarm Flashing, wide-angled alarm lens with dual red LEDs, plus alarm LCD readout
Audible alarm High-output, pulsing 85 dB at 1 ft. / 0.3 m (typical)
Confidence beep Every 5 seconds (field-selectable)
Other Low battery; off warning; sensor fail
Optional internal vibrator Vibrates in sync with audible and visual alarms
Continuous LCD Display Alphanumeric gas readout and status display advises:
Gas ppm or % Continuous displays of gas concentration present
TWA and STEL ppm or % Records and displays on demand
Peak ppm or % Records and displays peak (maximum) exposure to gas on demand
Setpoints Displayed on activation (auto) and on demand in ppm or %
Tests
Full function self-test Full function self-test on activation (auto)
General Specifications Impact-resistant ABS enclosure
Humidity 5% to 95% RH (non-condensing) (15% to 90% non-condensing for PH3 and NH3)
EMI/RFI Complies with EMC Directive 89/336/EEC
Battery type 3-volt lithium (camera battery available locally)
Battery life 3 years (9,000 hours)
Size 1.1 x 2.0 x 3.75 inches / 28 x 50 x 95 mm
Weight 2.9 oz. / 83 g

GasAlert Extreme reality photos